2018 Storm & Surface Water Engineering Standard Details

2018 Storm & Surface Water Engineering Standard Details


D-1     CONCRETE INLET

D-2     CATCH BASIN TYPE 1

D-3     CATCH BASIN TYPE 1-L

D-3A   CATCH BASIN TYPE 1-P

D-4     CATCH BASIN TYPE 2

D-5     LADDER, STEP, AND TOP SLAB, DETAILS

D-6     VANED GRATE

D-7     PARKING LOT/AREA GRATE

D-8     SOLID COVER

D-9     STANDARD FRAME INSTALLATION

D-10   THROUGH-CURB INLET FRAME

D-11   THROUGH-CURB INLET FRAME INSTALLATION

D-12   FRAME & GRATE FOR EXISTING ROLLED CURB

D-13   EXISTING ROLLED CURB FRAME & GRATE INSTALLATION

D-14   GRATE FOR EXISTING ROLLED CURB INSTALLATION

D-15   CONVERSION RISER FOR CATCH BASIN TYPE 1-L

D-16   AREA INLET

D-17   MANHOLE TYPE 1

D-18   MANHOLE TYPE 2

D-19   MANHOLE TYPE 3

D-20   MANHOLE TYPE 4

D-21   24” MANHOLE RING AND COVER

D-22   24” BOLT-LOCKING MANHOLE RING & COVER

D-23   MANHOLE/CATCH BASIN ADJUSTMENT DETAIL

D-24   CORRUGATED METAL MANHOLE

D-25   TYPICAL TRENCH DETAIL

D25A  PIPE ZONE BEDDING

D-26   FLOW CONTROL STRUCTURE

D-27   PIVOTING SHEAR GATE DETAIL

D-28   SCREW-TYPE SHEAR GATE

D-29   SHEAR GATE VALVE VAULT

D-29A VALVE BOX AND EXTENSIONINSTALLATION

D-29B VALVE OPERATING EXTENSION

D-30   DRY DETENTION PONDDRY DETENTION POND

D-30A WATER QUALITY POND

D-31   DETENTION PIPE

D-32   DETENTION VAULTDETENTION VAULT

D-33   TAPPING TEES FOR DRAIN PIPE

D-34   BEVELED END PIPE SECTION

D-35   ROCK-LINED DITCHES

D-36   GRASS-LINED DITCH

D-37   SIDEWALK DRAIN

D-38   ENERGY DISSIPATOR

D-39   DEBRIS CAGE

D-40   (NOT USED)

D-41   (NOT USED)

D-42   SPILL CONTROL (SC) SEPARATOR – TYPE 1

D-43   SPILL CONTROL (SC) SEPARATOR – TYPE 2

D-43A SPILL CONTROL (SC) SEPARATOR –TYPE 3

D-44    DRAINAGE FACILITY MAINTENANCE ACCESS

D-45    GATE/BOLLARD PLACEMENT

D-46    (NOT USED)

D-47    RUNOFF TREATMENT VAULT (WET VAULT)

D-48    COMBINED VAULT (DETENTION AND RUNOFF TREATMENT)

D-49    SUMP WITH RISER PIPE

D-50    (NOT USED)

D-51   TRAFFIC BEARING ACCESS FOR CORRUGATED METAL MANHOLE

D-52   CLEAN OUT TO GRADE

D-53   TRASH RACK/DEBRIS BARRIER

D-54   SOIL/CEMENT PIPE ANCHORS

D-55   (NOT USED)

D-56   CASING INSTALLATION

D-57   PIPE STAKE ANCHOR ASSEMBLY

D-58   DRIVEWAY CULVERT

D-59   ROCK PROTECTION OUTFALL

D-60   BIRD CAGE TRASH RACK STRUCTURE

NDP-1     AMENDED SOILS

NDP-2     BIORETENTION CELL

NDP-3     BIORETENTION SWALE

NDP-4     BIORETENTION PLANTER –WITH UNDERDRAIN

NDP-4A  BIORETENTION PLANTER – INFILTRATION

NDP-5    BIORETENTION PLANTER – UNDERDRAIN

              AND OVERFLOW CONNECTED TO STORM SYSTEM

NDP-6    BIORETENTION OVERFLOW WITH CONVEYANCE FURROW

NDP-7    BIORETENTION OVERFLOW WITH PIPE CULVERT

NDP-8    OVERFLOW CONFIGURATIONS FOR BIORETENTION

NDP-9    OBSERVATION PORT FOR BIORETENTION

NDP-10  DRAIN CURBCUT OPENING FOR BIORETENTION

NDP-11  POROUS ASPHALT OR PERVIOUS CONCRETE PAVEMENT SECTION

NPD-11A PERVIOUS ASPHALT OR CONCRETEPAVEMENT SECTION

NDP-12  PERMEABLE PAVER SYSTEMS PERMEABLE PAVER SYSTEMS

NDP-13  PERMEABLE PAVEMENT SIDEWALK IN PLANTING STRIP

NDP-14  PERMEABLE PAVEMENT SIDEWALK

NDP-15  CHECK DAM AND INTERCEPTOR FOR PERVIOUS PAVEMENT ON SLOPES

NDP-16  OBSERVATION PORT FOR PERMEABLE PAVEMENT

NDP-17  OBSERVATION PORT COVERS FOR PERMEABLE PAVEMENT

NDP-18  RAIN RECYCLING SYSTEM – RAIN BARREL

NDP-19  RAIN RECYCLING SYSTEM – CISTERN

NDP-20  POP-UP DRAINAGE EMITTER

NDP-21  REVERSE SLOPE SIDEWALK

NDP-22  ROOF DOWNSPOUT DISPERSAL TRENCH DETAIL

NDP-23  ROOF DOWNSPOUT INFILTRATION TRENCH

NDP-24  (NOT USED)

NDP-25  RESIDENTIAL ROOF DOWNSPOUT PERFORATED PIPE CONNECTION